SUND – Technical specifications
| Model | V in DC | V in AC * | P1 max | Net weight | Packaging dimensions |
Total weight |
|---|---|---|---|---|---|---|
| VDC | VAC | W | Kg | mm | Kg | |
| SUND 50 | 90 – 400 | 1×90 – 265 | 800 | 10,7 | 535x240x350(h) | 11,4 |
| Model | V in DC | V in AC * | P1 max |
|---|---|---|---|
| VDC | VAC | W | |
| SUND 50 | 90 – 400 | 1×90 – 265 | 800 |
| Model | Net weight | Packaging dimensions |
Total weight |
|---|---|---|---|
| Kg | mm | Kg | |
| SUND 50 | 10,7 | 535x240x350(h) | 11,4 |
General specifications
| Rated frequency | 50 – 60 Hz (+/- 2%) |
|---|---|
| Max liquid temperature | 40°C (104°F) |
| Max ambient temperature | -10 – 50°C (-14 – 122°F) |
| Max altitude at rated current | 1000 m |
| Protection degree | IP66 |
| Max current pressure | 3 bar |
| Max aspiration height | 2,5m |
| Motor insulation | F |
| Settable digital outputs N.O. or N.C. | 1. Motor run signal
2. Alarm signal |
| Analog inputs (10 or 15 VDC) | 1. 4-20 mA
2. 4-20 mA 3. 0 – 10 VDC 4. 0 – 10 VDC |
| Digital inputs | 4 digital inputs, configurable N.O. or N.C. for motor run/stop |
| Communication | RS485 MODBUS RTU, Bluetooth® SMART (4.0)) |